Heidenhain iTNC 530 (34049x-08) Manuale Utente Pagina 691

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 739
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 690
HEIDENHAIN iTNC 530 691
18.1 General user parameters
List of general user parameters
External data transfer
Adjusting TNC interfaces EXT1 (5020.0) and
EXT2 (5020.1) to an external device
MP5020.x
7 data bits (ASCII code, 8th bit = parity): Bit 0 = 0
8 data bits (ASCII code, 9th bit = parity): Bit 0 = 1
Block Check Character (BCC) any: Bit 1 = 0
Block Check Character (BCC) control character not permitted: Bit 1 = 1
Transmission stop through RTS active: Bit 2 = 1
Transmission stop through RTS inactive: Bit 2 = 0
Transmission stop through DC3 active: Bit 3 = 1
Transmission stop through DC3 inactive: Bit 3 = 0
Character parity even: Bit 4 = 0
Character parity odd: Bit 4 = 1
Character parity undesired: Bit 5 = 0
Character parity desired: Bit 5 = 1
Number of stop bits that are transmitted at the end of a character:
1 stop bit: Bit 6 = 0
2 stop bits: Bit 6 = 1
1 stop bit: Bit 7 = 1
1 stop bit: Bit 7 = 0
Example:
Use the following setting to adjust the TNC interface EXT2 (MP 5020.1) to
an external non-HEIDENHAIN device:
8 data bits, any BCC, transmission stop through DC3, even character
parity, character parity desired, 2 stop bits
Input for MP 5020.1: %01101001
Interface type for EXT1 (5030.0) and
EXT2 (5030.1)
MP5030.x
Standard transmission: 0
Interface for blockwise transfer: 1
Touch probes
Selecting signal transmission MP6010
Touch probe with cable transmission: 0
Touch probe with infrared transmission: 1
Probing feed rate for triggering touch
probes
MP6120
1 to 3000 [mm/min]
Maximum traverse to first touch point MP6130
0.001 to 99 999.9999 [mm]
Safety clearance to probing point during
automatic measurement
MP6140
0.001 to 99 999.9999 [mm]
Vedere la pagina 690